[DKSF 54.1 IU] Page HOME web interface

 

A main page contains brief information about a device (a model, a serial number, a software version) in settings of a web interface.

 

Information

A name of a device – is a domain name of a device, which is configured on the page Settings. It allows to distinguish several Netping devices of the same type. A name is displayed in a header of a web-interface, is sent in syslog messages and is available via SNMP – sysName.

A location of a device – is a description of a place of installation of a Netping device. It is configured on the page Settings. In addition, it is displayed in a header of a web-interface and is available via SNMP – sysLocation.

Contact data – are an administrator's contact data (usually an email). They are configured on the pafe Settings. This value is available via SNMP – sysContact.

A serial number – is a unique identification number of a device. It must coincide with a number on a sticker of a device. A serial number of a device cannot be changed.

MAC Address–– is a unique physical address of a device in the Ethernet network.

A model of a device – is a name of a model of a device.

Software version – is a current firmware version.

Hardware version – is a version of a printed circuit board and/or an assembly of the device.

Continuous operation time - is equipment operation time from the moment of the last turning on.

Network Configuration

IP address – is an IP address of a device.

A subnet mask – a subnetwork mask of a device.

Gateway – IP address of a gateway.

Backup Power

Power source - a power source is specified (mains electricity or a battery)

Battery charging - Yes/No