[DKSF 54.1 IU] Page TEMPERATURE web interface
On this page readings of temperature sensors that are connected to a device are displayed. Certain devices support connecting temperature sensors of TS WT and 1-wire types simultaneously (it can be clarified in the document named User Guide for a device). For TS and WT sensors, number of sensors 1..8 on a web-page of an interface correspond to the numbers labeled on cases of the sensors. Readings of TS and WT sensors will automatically appear in a web-interface 15s after a connection. A 1-Wire sensor is not recommended to be linked to a sensor Х, if TS or WT sensor with the number X is already connected to a device. 1-Wire sensors have a higher priority than TS and WT sensors. If a conflict arises, a device will display readings of 1-Wire sensor. To connect a 1-Wire sensor, there is a need to link its unique number to a sensor X in a filed “1W Sensor Unique Number”. Unique number of a 1-Wire sensor can be known using any Netping device supporting 1-Wire. To fulfill this: It is possible to plug up to 8 temperature sensors to a device. Temperature values and temperature sensors statuses are updated automatically more than once a minute with no need to reload a page manually. Note – is a filed for setting up a brief description of a temperature sensor. A note is used in Syslog and Logfile notifications as well as included into Trap notifications. Its maximum size is 16 characters. On default: empty Current temperature, °C – displays a current temperature of a sensor in degrees of Celsius. A temperature value is occasionally updated automatically without reloading a web-page. Status – displays a current status of a temperature sensor. Possible values: Upper limit of Safe range, °C - is a field for setting up an upper limit of a temperature range for each temperature sensor. A temperature range is used to indicate conditions of TRAP and Syslog notifications generating. On default: 60 Lower limit of Safe range, °C - is a field for setting up a lower limit of a temperature range for each temperature sensor. A temperature range is used to indicate conditions of TRAP and Syslog notifications generating. On default: 10 When clicking the button "Settings" there appears a menu of settings for sending notifications to the following directions: Logfile, Syslog, E-mail, SMS and SNMP Trap t° is above safe range – is a checkbox, when checked a device will send notifications if a current temperature of a temperature sensor exceeds an upper limit of a safe range for this temperature sensor. On default: checkbox is not checked t° is in safe range –is a checkbox, when checked a device will send notifications if a current temperature of a temperature sensor is back to a safe range for this temperature sensor. On default: checkbox is not checked t°is below safe range – is a checkbox, when checked a device will send notifications if a current temperature of a temperature sensor falls below a safe range for this temperature sensor. On default: checkbox is not checked Sensor fault – is a checkbox, when checked a device will send notifications if a connection with a sensor is lost. On default: 0 Include in Summary Report - is a checkbox, when checked reports about a sensor status will be sent via an e-mail and/or an sms. A time for sending reports is indicated on the page SMS and E-MAIL settings. After setting all necessary changes click the button «Apply changes».