Information in the section applies to the device UniPing server solution v3/SMS with a built-in GSM modem.

...

t – is a current temperature, °C

label – is a label of a temperature sensor, it is specified in the field «Memo» on the page «TEMPERATURE» of a device web interface. A label in the text of a notification is quoted. If a label is not specified (empty), then it is not included into SMS.

...

Info
iconfalse

TEMP.SENSOR n "label" OUT OF RANGE (t1 TO t2), NOW tC

where:

n – is a number of a temperature sensor, 1..8

t1, t2 – is thresholds of a normal temperature range, °C

t – is a current temperature, °C

label – is a label of a temperature sensor, it is specified in the field «Memo» on the page «TEMPERATURE» of a device web interface. A label in the text of a notification is quoted. If a label is not specified (empty), then it is not included into SMS

...

t – is a current temperature, °C

h_status – is a humidity status, its possible values are: «below normal», «normal», «above normal»

t_status – is a temperature status, its possible values are: «below normal», «normal», «above normal»

label – is a label of a humidity sensor, it is specified in the field «Memo» on the page «HUMIDITY» of a device web interface. A label in the test of a notification is quoted. If a label is not specified (empty), then it is not included into SMS

...

h1, h2 – are the thresholds of a normal relative humidity range, %

label – is a label of a humidity sensor, which is specified in the field «Memo» on the page «HUMIDITY» of a device web interface. A label in the text of a notification is quoted. If a label is not specified (empty), then it is not included into SMS


A notification about the notifications of a relative humidity entering the normal specified range:

...

h1, h2 – are the thresholds of the normal relative humidity range, %

label – is a label of a humidity sensor, it is specified in the field «Memo» on the page «HUMIDITY» of a device web interface. A label is quoted in a text of a notification. If a label is not specified (empty), then it is not included into SMS


A notification about the readings of a relative humidity increasing the specified range:

...

h1, h2 – are the thresholds of a normal relative humidity, %

label – is a label of a humidity sensor, it is set in the field «Memo» on the page «HUMIDITY» of a device web interface. A label is quoted in a text. If a label is not set (empty), then it is not included into SMS


A notification about temperature reading decreasing below a specified range (a temperature sensor is built into a relative humidity sensor):

...

t – is a current temperature, °C

t1, t2 – are the thresholds of a normal temperature range, °C

label – is a label of a humidity sensor, it is specified in the field «Memo» on the page «HUMIDITY» of a device web interface. A label is quoted in a text of a notification. If a label is not set (empty), then it is not included into SMS

 

A notification about temperature readings entering the normal specified range (a temperature sensor is built into a relative humidity sensor):

...

t – is a current temperature, °C

t1, t2 – are the thresholds of normal temperature range, °C

label – is a label of a humidity sensor, which is set in the field «Memo» on the page «HUMIDITY» of a device web interface. A label is quoted in a text of a notification. If a label is not set (empty), then it is not included into SMS


A notification about temperature readings leaving a specified range (a temperature sensor is built into a relative humidity sensor):

...

t – is a current temperature, °C

t1, t2 – are the thresholds of a normal temperature range, °C

label – is a label of a humidity sensor, which is set in the field «Memo» on the page «HUMIDITY» of a device web interface. A label is quoted in a text of a notification. If a label is not set (empty), then it is not included into SMS


A notification about an analogue analog smoke sensor switching to a normal status:

Info
iconfalse

ANALOG SMOKE SENSOR: OK


A notification about analogue analog smoke sensor switching to a status switched off (power is switched off):

Info
iconfalse

ANALOG SMOKE SENSOR: NOT POWERED


A notification about an analogue analog smoke sensor switching to the status «Alarm»:

Info
iconfalse

ANALOG SMOKE SENSOR: ALARM!


A notification about an analogue analog smoke sensor switching to the status «Open loop»:

Info
iconfalse

ANALOG SMOKE SENSOR: FAILED (OPEN LOOP)


A notification about an analogue analog smoke sensor switching to the status «Short circuit»:

Info
iconfalse

ANALOG SMOKE SENSOR: FAILED (SHORT CIRQUITCIRCUIT)


A notification about switching on/off a built-in relay:

...

A notification about restoring/losing of a losing a connection of a tested node in a network (the module «Pinger»):

...

A feature of sending a daily report as SMS notification about a status of sensors, IO lines, and relays is implemented in a device. More detailed information about configuring the time of sending this report can be read in the section «[ENG] 11.9. [DKSF 70/71.6 IU] Configuring Time of Sending a Daily Report about a Status of Sensors, IO Lines and Relays as SMS Notifications».